Original And New Cisco AC power supply Catalyst 6500 3000W WS-CAC-3000W=
Product Information
The 3000 W AC-input power supply designed for the Cisco Catalyst 6509-NEB-A Switch, called the WS-CAC-3000W, requires single-phase source AC. Source AC can be out of phase between multiple power supplies or multiple AC-power plugs on the same power supply because all AC power supply inputs are isolated. We offer pre-owned and new WS-CAC-3000W power supplies to enhance your network.
The 3000 W AC-input power supply (WS-CAC-3000W) is supported in the following Catalyst 6500 series switches:
Table 1 lists the specifications for the 3000 W AC-input power supply.
Specification | Description |
AC-input type | Autoranging input with power factor correction (PFC). |
Note Power factor correction is a standard feature on all Catalyst 6500 series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. | |
AC-input voltage | Low-line (120 VAC nominal)—90 VAC (min) to 132 VAC (max) |
High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max) | |
AC-input current | 16 A @ 200 VAC (3000 W output) |
16 A @ 100 VAC (1400 W output) | |
AC-input frequency | 50/60 Hz (nominal) (±3% for full range) |
Power supply output capacity | 1400 W maximum (100–120 VAC) |
3000 W maximum (200–240 VAC) | |
Front panel power connector | A two-pin male Molex connector is located in the lower right corner of the power supply front panel. The connector provides 42 VDC at a maximum of 17 A. This connector provides power to the WS-6509-NEB-UPGRD kit fan assembly through a power harness also provided in the kit. A hinged protective flap secured by a captive screw covers the connector when it is not in use. |
Output holdup time | 20 ms minimum |
kVA rating23 | 3520 W (total input power) or 3.6 KVA (high-line operation) |
Heat dissipation | 12,046 BTU/hour (approx.) |
Weight | 15.8 lb (7.2 kg) |
Table 2 show the 3000 W AC-Input Power Supply LEDs
LED | Meaning |
INPUT OK | Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.) |
Off—Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. | |
FAN OK | Green—Power supply fan is operating properly. |
Off—Power supply fan failure is detected. | |
OUTPUT FAIL | Red—Problem with one or more of the DC-output voltages of the power supply. |
Off—DC-output voltages within acceptable margins. | |
Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. | |
42V OK | Green—42 VDC is present at the fan power connector. |
Off—42 VDC is not present at the fan power connector. |
Show the appearance of WS-CAC-3000W=
Our Advantage
1.100% Cisco original factory sealed clean serial.
2. Extensive Real Inventory
3. Save up 50%-92% off the Global Price list
4. Flexible payment shipment
5. Unparalleled Experience Service
Shipping
1. Fast: in 2-3 days upon receipt of payment.
2. Safe: original package with protection foam in case of equipment broken in transportation
3. Economic: Low cost express fee via DHL, Fedex, TNT,EMS,Postal etc.
4. Flexible: We also ship to your Assigned Forwarder or Pickup by your forwarder